Cookie Img
Home » Products » Public Addressing System

Public Addressing System

Public Addressing System
Public Addressing System
Product Code : GT-18
Brand Name : GEESYS TECHNOLOGIES
Product Description

We are recognized as a master manufacturer, supplier and exporter of GEESYS Public Addressing System, This is an automatic fire alarm system which is developed for detecting the unwanted presence of fire by monitoring climate changes associated with combustion. Generally, a fire alarm system is either classified as manually and automatically activated, or both. Automatic fire alarm system can be utilized to inform people to evacuate in the event of a fire or other emergency, to summon emergency forces help, and to get ready the structure and associated systems in order to control the spread of smoke and fire. Made from supreme components, this GEESYS Public Addressing System is offered to clients at negotiable prices.

Main Functional Features:

  • Smart equalizing for superb sound and speech reproduction
  • Easy-to-use with zone labeling and setting indicators
  • Out-of-box functionality with no training required
  • Premium products with future-proof expandability
  • Stylish, subtle European design
  • Reduced and easy maintenance
  • Simple, reduced and economical field cabling.
  • Flexibility to connect the loudspeakers at longer distance.
  • Trouble free system.
  • Modular architecture.
  • Flexibility to build the system for the present need with enough provision for future expansion.
  • Monitoring the healthiness of all associated equipment in the PA System
  • Connectivity of p. a. system with the EPABX System.


Specifications:

Parameters

Array configuration

String configuration

Model

GETCETINV

GETSTRINV

Maximum DC Input Range

1000V

1000V

No of DC Inputs

2 - 16

2 - 24

No of DC Outputs

1

1 - 8

Number of Terminal Blocks

4 - 34

4 - 48

Reverse Blocking Diode, No’s

2 - 12

2 - 24

Maximum Input Fuse* Rating, A

3/5/10/12/15/20/30

12/16/32/40/63

Maximum string current per fuse holder with all string fuse**

Reduction factor 0.55

Reduction factor 0.55

Maximum DC Current, A

100

192

Maximum Continuous Current, A

160

240

Isolator/MCB*, A

16/32/40/63

16/32/40/63

Maximum Voltage, VDC

600/1000

600/1000

+Ve Input Wire Size,1C x sqmm

2.5 - 10

4 - 25

-Ve Input Wire Size, 1C x sqmm

2.5 - 10

4 - 25

MOV

110/680V

110/680V

Surge Protection Device (SPD)*

600/1000V, Class II

600/1000V, Class II

Operating Temperature

-25 to 55

-25 to 55

Enclosure Type

PS/PC*

PS/PC*

Protection Type/Protection Class

IP65

IP65

Connectors* @ Output

MC4/MC3

MC4/MC3

Cable gland clamping range, mm

12 - 32

12 - 32

Wall mounting

Yes

Yes

Bus Bar*

Yes

Yes

Operating conditions

Temp : -20 to +55 Deg. C ; RH : 0 - 95% non cond

Type of Protections(As per Clients requirement)

Short-Circuit, Surge

Short-Circuit, Surge

International standards followed

IEC 60364

IEC 60364

Disconnection switch

Optional

Optional

Design Life

25 years +

*Optional Features

Application:

  • Restaurants
  • Retail spaces
  • Office buildings
  • Houses of worship
  • Hotels
  • Schools
  • Community centers
  • Public buildings
  • Tourist boats and ferries

GEESYS Technologies (India) Private Limited

Contact Us

( *represents compulsory fields )

Tips on getting accurate quotes. Please include product name, order quantity, usage, special requests if any in your inquiry.